Home    中文  
 
  • Search
  • lucene Search
  • Citation
  • Fig/Tab
  • Adv Search
Just Accepted  |  Current Issue  |  Archive  |  Featured Articles  |  Most Read  |  Most Download  |  Most Cited

Chinese Journal of Heart and Heart Rhythm(Electronic Edition) ›› 2022, Vol. 10 ›› Issue (02): 96-100. doi: 10.3877/cma.j.issn.2095-6568.2022.02.006

Special Issue:

• Leadless Pacemaker • Previous Articles     Next Articles

The incidence and clinical characteristics of femoral vein thrombus after leadless pacemaker implantation

Xueying Chen1, Jingfeng Wang1, Yixiu Liang1, Jin Bai1, Wei Wang1, Shengmei Qin1, Lei Zhang1, Minghui Li1, Jiahui Chen1, Yangang Su1,()   

  1. 1. Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, National Clinical Research Center for Interventional Medicine, Shanghai 200032, China
  • Received:2022-05-06 Online:2022-06-25 Published:2022-08-05
  • Contact: Yangang Su

Abstract:

Objective

To investigate the incidence and clinical characteristics of femoral vein thrombus after leadless pacemaker implantation.

Methods

The patients received leadless pacemaker implantation in Zhongshan Hospital, Fudan University from April 2020 to January 2021 were consecutively included. All of the patients suffered from bradycardia were indicated for a single chamber pacemaker implantation and received femoral vein ultrasound at the first day post-procedure. The incidence and the clinical characteristics were described and the correlation factors were analyzed.

Results

One hundred and forty-six patients were enrolled. The incidence of femoral vein thrombus was 2.74% (4/146). The average age of these 4 cases was (75.75±19.14) years old with 3 males,and all the patients were asymptomatic. During follow-up, there were no adverse outcomes happened, including thromboembolism with the thrombus. The femoral vein thrombus of 3 cases disappeared at 1 month's follow-up, and 1 case disappeared at 2 months post-procedure. In thrombus group, elevation of D-dimmer (>0.5 mg/L) were documented in 1 case (25.00%) pre-procedure, and 3 cases (75.00%) post-procedure while the median level of D-dimmer pre-procedure were not significantly different as compared to post-procedure [0.33(0.26,0.94) mg/L vs.1.49(0.67,2.17) mg/L,P=0.057)].The occurrence of femoral vein thrombus after leadless pacemaker implantation was significantly associated with D-dimmer elevation post-procedure by Spearman correlation analysis (r=0.239,P=0.037). While it was not significantly correlated to the other factors including age, gender, body weight, comorbidities (atrial fibrillation, hypertension and diabetes), baseline echocardiographic parameters, D-dimmer elevation pre-procedure, fluoroscopic time and closure methods (all P>0.05).

Conclusion

The incidence of femoral vein thrombus was rather low. Monitoring D-dimmer and performing puncture site ultrasound post-procedure are helpful to detect femoral vein thrombus and start anticoagulation in time.

Key words: Pacemaker, artificial, Femoral vein thrombus, Incidence, Clinical characteristics